BlueSolar PWM-Light 12/24V-10A
In stock
Technical specifications
Technical specifications
| Product use | Régulation de charge solaire pour systèmes de batteries 12/24V |
| Type de régulateur solaire | PWM |
| Max charge current (A) | 10 |
| Nominal voltage | 12/24 |
| Plage de tension d'entrée solaire | 0-55 |
| Absolute maximale solar tension | 55 |
| Chimies de batterie supportées | Plomb-acide scellée,Gel,Plomb-acide à électrolyte liquide |
| Nombre d'entrées panneaux solaires | 1.0 |
| Sortie consommateur supportée | Oui |
| Nombre d'étapes de charge | 3.0 |
| Compensation de température | Oui |
| Wired network | Aucun |
| Cooling method | Convection naturelle |
| Protection features | Surcharge,Court-circuit,Inversion de polarité,Surchauffe |
| Display type | Affichage 7 segments à deux chiffres |
| Configuration software name | Aucun |
| Mounting type | Montage mural vertical |
| IP rating | IP20 |
| Operating temperature range | -20 à +50 |
| Housing material | Plastique |
| Weight | 0.15 |
| Dimensions (W x H x D) | 133 x 70 x 33.5 |
| Déconnexion automatique de la charge | Oui |
| Charge Voltage Absorption Range | 14.2V / 28.4V |
| Charge Voltage Float Range | 13.8V / 27.6V |
| Type de mise à la terre | Positif commun |
| Low Battery Disconnect Voltage 12v Range | 11.2 |
| Low Battery Disconnect Voltage 24v Range | 22.4 |
| Max Humidity Non Condensing | Max 95% |
| Overload Shutdown Time 130 Percent | 60 |
| Overload Shutdown Time 160 Percent | 5 |
| Power Consumption Current Max | < 10 |
Detailed description
Detailed description
Designed for 12/24V solar systems, the Victron Energy BlueSolar PWM-Light 10A charge controller provides efficient energy management with automatic system voltage detection. This controller uses pulse-width modulation (PWM) to optimize battery charging and improve performance, relying on a multi-stage charging algorithm.
Features and Protections
The BlueSolar PWM-Light 10A includes a load output with low-battery disconnect, plus a lighting control function with a single timer. A two-digit seven-segment display simplifies adjustment of load output features, including the timer. Battery charging occurs in three non-programmable stages: bulk, absorption, and float. Protections include overcurrent on the load output, short circuits, solar panel/battery reverse polarity, and overheating. In case of overcurrent, the system stops after 60 seconds for a 130% load and after 5 seconds for a 160% load. A short circuit causes immediate shutdown.
Technical Specifications
This charge controller supports a nominal charging current of 10A and a maximum solar voltage of 28V for 12V systems (36-cell panels) or 55V for 24V systems (72-cell panels). Standby consumption is less than 10 mA. Absorption voltage is 14.2V for 12V systems and 28.4V for 24V systems, while float voltage is 13.8V (12V) and 27.6V (24V). Low-voltage load disconnect occurs at 11.2V / 22.4V, with automatic reconnect at 13.1V / 26.2V or manual reconnect at 12.6V / 25.2V. The controller operates from -20 to +50°C at full load. It is rated IP20, indicating protection against solid objects larger than 12.5 mm but no water resistance. Dimensions are 70 x 133 x 33.5 mm with a weight of 0.15 kg, and it uses 5 mm² / AWG10 terminals. Wiring is positive common.
Expert opinion
Expert opinion
« Analyse du régulateur Victron BlueSolar PWM-Light 10A »
Your payment information and data are processed securely.