SmartShunt 500A/50mV
In stock
Technical specifications
Technical specifications
| Battery technology | Compatible with Lead-acid, Lithium |
| Integrated battery monitoring | Oui |
| Wired network | VE.Direct |
| Max charge current (A) | 500.0 |
| Max discharge current (A) | 500.0 |
| Terminal size | M10 |
| Mounting orientation | All orientations |
| Operating temperature range | -40 to +50 |
| Storage temperature range | -40 to +50 °C |
| IP rating | IP21 |
| Weight | 0.3 |
| Alarm output | None (via VictronConnect app or GX device) |
| Résolution Ampères-heures | 0.1 |
| Available alarms | Low/high voltage, low SoC, low/high starter battery voltage, low/high temperature, midpoint deviation |
| Nombre de parcs de batteries | 2 |
| Protocole de communication | Bluetooth, VE.Direct |
| Précision du courant | 0.4 |
| Consommation électrique (mA) | 1 |
| Plage de mesure de courant | -500 to 500 |
| Compatible CZone | No |
| Display type | None (use a smartphone/tablet via the VictronConnect app) |
| Plage de tension d'entrée auxiliaire | 6.5 - 70 |
| Compatible MasterBus | No |
| Plage de tension mesurée | 6.5 to 70 |
| Mounting type | Surface mount |
| Operating voltage range | 6.5 to 70 |
| Power source | Battery (6.5 - 70 VDC) |
| Dimensions du produit (L x l x H) | 46 x 120 x 54 |
| Surveillance batterie de service | Complete (charge state, voltage, current, remaining time) |
| Shunt inclus | Yes (built-in) |
| Courant nominal du shunt | 500 |
| Spécification du shunt | 500A / 50mV |
| Surveillance batterie de démarrage | Voltage only (via auxiliary input) |
| Résolution État de charge | 0.1 |
| Plage de mesure de température | -20 to +50 |
| Résolution Temps restant | 1 |
| Précision de tension | 0.3 |
| Résolution de la tension | 0.01 |
Detailed description
Detailed description
The Victron Energy SmartShunt 500A/50mV shunt is an all-in-one battery monitoring solution designed for systems requiring precise tracking without the bulk of a dedicated display. It differs from counterparts like the BMV-712 battery monitor by lacking an integrated display, programmable visual/sound alarms, and a programmable relay, thus offering simplified installation and reduced wiring. Data access is via the VictronConnect app on a smartphone or tablet, connected via Bluetooth, displaying state of charge, remaining autonomy, and history.
Integration and flexibility of the SmartShunt
This SmartShunt 500A/50mV features a VE.Direct port for seamless integration with Victron GX devices, enabling centralized system management. Its versatile auxiliary input can monitor the voltage of a second battery (such as a starter battery), the midpoint of a battery bank, or connect an optional temperature sensor (ASS000100000). This flexibility makes it a key component for optimized monitoring of complex battery banks.
Technical performance and robustness
The Victron Energy SmartShunt 500A/50mV shunt operates within a supply voltage range of 6.5 to 70 VDC with current consumption below 1 mA. It supports battery capacities from 1 to 9999 Ah and functions in a temperature range of -40 to +50°C. Its compact dimensions (46 x 120 x 54 mm) and M10 connection bolts facilitate integration. It offers a measurement accuracy of ±0.01 A for current and ±0.01 V for voltage, with an IP21 protection rating for the standard version, and an IP65 version is available for harsher environments. The device compensates for the Peukert effect and improves charging efficiency by sharing data with connected chargers via VE.Smart Networking.
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« The SmartShunt 500A/50mV: intelligent and integrated battery monitoring »
Your payment information and data are processed securely.