Low-voltage disconnect m-LVD
In stock
Technical specifications
Technical specifications
| Nominal voltage | 12 |
| Terminal size | M6 (1/4"-20) |
| IP rating | IP67 |
| Protection AFD | No |
| Alarm Time Before Disconnect | 5 |
| Courant continu (A) | 65.0 |
| Type de contrôle | Remote switch |
| Dimensions (W x H x D) | 70 x 70 x 50 |
| Disconnect Voltage Range | 11.3V - 12.1V |
| Factory Default Disconnect Voltage | 12.1 |
| Courant intermittent (A) | 115 (5 min) |
| Verrouillable à clé | No |
| Mounting type | Surface, front panel or rear panel |
| Nombre de pôles | 1 |
| Operating Current Connected Ma | 95 |
| Operating Current Open Ma | 4 |
| Operating voltage range | 11.3V - 13.5V DC (nominal 12V DC) |
| Diamètre de découpe du panneau | 58.7 |
| Positions | Disconnect voltage adjustment, Override, Stop |
| Product use | Automatically disconnects non-essential loads to preserve the battery and ensure engine start-up. |
| Reconnect Voltage | 13 |
| Remote Control Switch Included | Yes |
| Switch type | Automatic low-voltage disconnect |
| Type de borne | Threaded stud |
| Time Delay To Alarm | 5 |
| Total Disconnect Delay | 10 |
| Type de connexion câblage | Stud mount |
Detailed description
Detailed description
Designed for intelligent power management of 12V DC systems, the BLUE SEA m-LVD Low Voltage Disconnect is an automatic low-voltage disconnect device. It protects batteries from deep discharge by automatically cutting non-essential loads when battery voltage drops below a preset threshold. This function preserves energy needed for engine start or extends battery life.
Technical Specifications and Key Features
The m-LVD operates at a nominal voltage of 12V DC, with a continuous current rating of 65A and an intermittent rating of 115A for 5 minutes. Its disconnect voltage is adjustable from 11.3V to 12.1V, with a factory setting of 12.1V. The system includes a 5-minute delay before activating an alarm (if optional) when voltage falls below the threshold, followed by an additional 5-minute delay before effective disconnection, totaling 10 minutes. Reconnection occurs automatically when voltage exceeds 13.0V for 2 minutes or 13.5V for 30 seconds. Operating current is 95mA when connected and 4mA when open.
The disconnect device ships with the PN 7928 remote control switch, which allows adjustment of the disconnect voltage, activation of an "Override" mode delaying disconnection by 10 minutes, or manual circuit cutoff via the "OFF" function. The switch also disables the optional audible alarm. The m-LVD is IP67 rated for temporary immersion and meets external ignition protection requirements per ISO 8846 and SAE J1171. It supports cables up to 1/0 AWG (50mm²) with 1/4"-20 (M6) terminal studs requiring 60 in-lb (6.78 Nm) torque. Unit weight is not specified in provided documentation or web sources.
Integration and Positioning
While products like BLUE SEA manual battery switches or ACR load distributors handle isolation or load distribution respectively, the m-LVD serves as a proactive battery protection component. It differs from a simple battery switch by its automation and ability to specifically manage non-essential loads. Compared to more complex solutions featuring multifunction battery managers, the m-LVD provides a targeted and simplified solution for low-voltage disconnection, particularly suited to 12V DC installations requiring reliable protection against deep discharge without the complexity of a full system.
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« Smart 12V DC battery protection: expert review of the m-LVD disconnect »