Skip to content

New

Skysat delivers its products throughout the European Union 🇪🇺

SAHARA MK2 1200 12V AFCTN

Collection: Bilge pumps

Bilge and transfer pumps for dewatering, evacuation, and onboard pumping systems.

18 products

SAHARA MK2 1200 12V AFCTN

Attwood

Attwood Sahara MK2 1200 12 V automatic bilge pump

Ref : 5512-7

Regular price £86.20 GBP
Sale price £86.20 GBP Regular price
excl. tax
Pompe de cale automatique Supersub Smart 650 - 12 V Whale – référence SS5212

Whale

Supersub Smart 650 automatic bilge pump - 12 V

Ref : SS5212

Regular price £86.42 GBP
Sale price £86.42 GBP Regular price £98.04 GBP
excl. tax
Pompe de cale Supersub 500 - 12 V Whale – référence SS5012

Whale

Supersub 500 Bilge Pump - 12 V

Ref : SS5012

Regular price £48.23 GBP
Sale price £48.23 GBP Regular price £60.85 GBP
excl. tax
Pompe de cale automatique Supersub 1100 - 24 V Whale – référence SS1224
En cours de reappro

Whale

Supersub 1100 - 24 V automatic bilge pump

Ref : SS1224

Regular price £147.50 GBP
Sale price £147.50 GBP Regular price £186.07 GBP
excl. tax
Pompe de cale automatique Supersub 1100 - 12 V Whale – référence SS1212

Whale

Supersub 1100 - 12 V Automatic Bilge Pump

Ref : SS1212

Regular price £143.58 GBP
Sale price £143.58 GBP Regular price £181.12 GBP
excl. tax
Système de cale automatique Bilge IC - 24 V Whale – référence SI8484
En cours de reappro

Whale

Whale Bilge IC 24 V Automatic Bilge Pump System

Ref : SI8484

Regular price £409.82 GBP
Sale price £409.82 GBP Regular price £517.00 GBP
excl. tax
Système de cale automatique Bilge IC - 12 V Whale – référence SI8284
En cours de reappro

Whale

Whale Bilge IC 12V Automatic Bilge System

Ref : SI8284

Regular price £401.24 GBP
Sale price £401.24 GBP Regular price £506.17 GBP
excl. tax
Crépine de cale à entrée latérale 19 mm Whale – référence SB3422

Whale

Side-entry bilge strainer 19 mm

Ref : SB3422

Regular price £54.52 GBP
Sale price £54.52 GBP Regular price £59.76 GBP
excl. tax
Clapet anti-retour en ligne 19/25 mm Whale – référence LV1219
En cours de reappro

Whale

Inline check valve 19/25 mm

Ref : LV1219

Regular price £21.36 GBP
Sale price £21.36 GBP Regular price £26.94 GBP
excl. tax
Contacteur de niveau Field Switch Whale – référence BE9003

Whale

Field Switch Level Switch

Ref : BE9003

Regular price £60.93 GBP
Sale price £60.93 GBP Regular price £67.14 GBP
excl. tax
Mini Puppy 24 V 6 l/min Jabsco 23620-4103

Jabsco

Mini Puppy 24 V 6 l/min

Ref : J016

Regular price £330.72 GBP
Sale price £330.72 GBP Regular price £366.14 GBP
excl. tax
Utility Puppy 3000 24 V 50 l/min Jabsco 23920-2323

Jabsco

Utility Puppy 3000 24 V 44 l/min at 3 m

Ref : J028

Regular price £339.61 GBP
Sale price £339.61 GBP Regular price £370.78 GBP
excl. tax
Water Puppy 2000 12 V Jabsco 23680-4003

Jabsco

Water Puppy 2000 12 V

Ref : J019

Regular price £169.43 GBP
Sale price £169.43 GBP Regular price £193.63 GBP
excl. tax
Mini Puppy 12 V 6 l/min Jabsco 23620-4003

Jabsco

Mini Puppy 12 V 6 l/min

Ref : J015

Regular price £320.37 GBP
Sale price £320.37 GBP Regular price £366.14 GBP
excl. tax
Utility Puppy 2000 12 V 38 l/min Jabsco 23920-2423

Jabsco

Utility Puppy 2000 12 V 29.5 l/min at 3 m

Ref : J025

Regular price £385.80 GBP
Sale price £385.80 GBP Regular price £427.39 GBP
excl. tax
Utility Puppy 3000 12 V 50 l/min Jabsco 23920-2223

Jabsco

Utility Puppy 3000 12 V 44 l/min at 3 m

Ref : J027

Regular price £615.15 GBP
Sale price £615.15 GBP Regular price £703.03 GBP
excl. tax
Water Puppy 2000 24 V Jabsco 23680-4103

Jabsco

Water Puppy 2000 24 V

Ref : J020

Regular price £169.43 GBP
Sale price £169.43 GBP Regular price £193.63 GBP
excl. tax
Utility Puppy 2000 24 V 38 l/min Jabsco 23920-2523

Jabsco

Utility Puppy 2000 24 V 29.5 l/min at 3 m

Ref : J026

Regular price £339.97 GBP
Sale price £339.97 GBP Regular price £388.53 GBP
excl. tax

Learn more

Bilge pump: evacuating water from the boat’s lowest point

An electric bilge pump removes water that collects at the lowest point of the hull. This collection includes 12 V and 24 V Whale and Jabsco pumps, automatic systems, and installation accessories. Manual pumps are in the manual bilge pumps collection. For the full method, read our guide bilge pump: flow rate, installation, and safety.

The families in this collection

How to choose: actual flow rate, voltage, automation

  • Actual flow rate, not the box rating. Commercial flow rates are measured under manufacturer-defined conditions. On board, the discharge head, hose length and diameter, elbows, valves, and available voltage reduce them. Compare performance curves or tables at the intended head for your boat.
  • Voltage. Choose a pump that matches the boat’s system voltage, 12 V or 24 V, and size the cable so it receives its rated voltage when running: voltage drop slows the motor.
  • Automatic or manual control. An automatic pump has an integrated sensor or uses a separate float, such as the Field Switch. In either case, the system must remain manually testable; a three-position switch (off, automatic, forced) often provides this.
  • Two levels and an alarm. A small pump at the lowest point removes routine water; a second, higher pump takes over in abnormal rises and triggers an alarm on a separate sensor. The number and capacity of pumps depend on the boat and its requirements.

Installation: the details that make the difference

  • Place the intake at the true lowest point, both afloat and under way, with the strainer accessible for cleaning.
  • Keep the discharge hose at the recommended diameter, short, and free of crushed bends.
  • Prevent backflow and siphoning: outlet above the waterline per the manual, vented loop if needed. An inline non-return valve is not always necessary: it adds pressure loss and a risk of blockage.
  • Protect the circuit with a fuse or circuit breaker sized per the manual and clearly label the pump on the electrical panel.

Common mistakes

  • Choosing based on the rated flow alone, without accounting for head and hose.
  • Leaving an automatic pump without an alarm: a continuously running pump can mask a water ingress until batteries are drained.
  • Removing the manual pump: it remains usable after battery, wiring, sensor, or motor failure.

Skysat advice

Test the installation with water: pour a measured amount into the bilge, verify automatic activation, time the evacuation, and check the discharge. Whale states in its manuals that a bilge pump may not suffice in the event of a rapid flooding: it handles flowing water and buys time, but does not replace locating the leak.