Skip to content
SAHARA MK2 1200 12V AFCTN

Collection: Bilge pumps

Bilge and transfer pumps for dewatering, evacuation, and onboard pumping systems.

18 products

SAHARA MK2 1200 12V AFCTN

Attwood

Attwood Sahara MK2 1200 12 V automatic bilge pump

Ref : 5512-7

Regular price £86.06 GBP
Sale price £86.06 GBP Regular price
excl. tax
Pompe de cale automatique Supersub Smart 650 - 12 V Whale – référence SS5212

Whale

Supersub Smart 650 automatic bilge pump - 12 V

Ref : SS5212

Regular price £86.28 GBP
Sale price £86.28 GBP Regular price £97.88 GBP
excl. tax
Pompe de cale Supersub 500 - 12 V Whale – référence SS5012

Whale

Supersub 500 Bilge Pump - 12 V

Ref : SS5012

Regular price £48.16 GBP
Sale price £48.16 GBP Regular price £60.75 GBP
excl. tax
Pompe de cale automatique Supersub 1100 - 24 V Whale – référence SS1224
En cours de reappro

Whale

Supersub 1100 - 24 V automatic bilge pump

Ref : SS1224

Regular price £147.26 GBP
Sale price £147.26 GBP Regular price £185.76 GBP
excl. tax
Pompe de cale automatique Supersub 1100 - 12 V Whale – référence SS1212

Whale

Supersub 1100 - 12 V Automatic Bilge Pump

Ref : SS1212

Regular price £143.35 GBP
Sale price £143.35 GBP Regular price £180.82 GBP
excl. tax
Système de cale automatique Bilge IC - 24 V Whale – référence SI8484
En cours de reappro

Whale

Whale Bilge IC 24 V Automatic Bilge Pump System

Ref : SI8484

Regular price £409.14 GBP
Sale price £409.14 GBP Regular price £516.15 GBP
excl. tax
Système de cale automatique Bilge IC - 12 V Whale – référence SI8284
En cours de reappro

Whale

Whale Bilge IC 12V Automatic Bilge System

Ref : SI8284

Regular price £400.58 GBP
Sale price £400.58 GBP Regular price £505.33 GBP
excl. tax
Crépine de cale à entrée latérale 19 mm Whale – référence SB3422

Whale

Side-entry bilge strainer 19 mm

Ref : SB3422

Regular price £54.43 GBP
Sale price £54.43 GBP Regular price £59.66 GBP
excl. tax
Clapet anti-retour en ligne 19/25 mm Whale – référence LV1219
En cours de reappro

Whale

Inline check valve 19/25 mm

Ref : LV1219

Regular price £21.32 GBP
Sale price £21.32 GBP Regular price £26.89 GBP
excl. tax
Contacteur de niveau Field Switch Whale – référence BE9003

Whale

Field Switch Level Switch

Ref : BE9003

Regular price £60.83 GBP
Sale price £60.83 GBP Regular price £67.03 GBP
excl. tax
Mini Puppy 24 V 6 l/min Jabsco 23620-4103

Jabsco

Mini Puppy 24 V 6 l/min

Ref : J016

Regular price £330.18 GBP
Sale price £330.18 GBP Regular price £365.54 GBP
excl. tax
Utility Puppy 3000 24 V 50 l/min Jabsco 23920-2323

Jabsco

Utility Puppy 3000 24 V 44 l/min at 3 m

Ref : J028

Regular price £339.05 GBP
Sale price £339.05 GBP Regular price £370.17 GBP
excl. tax
Water Puppy 2000 12 V Jabsco 23680-4003

Jabsco

Water Puppy 2000 12 V

Ref : J019

Regular price £169.15 GBP
Sale price £169.15 GBP Regular price £193.31 GBP
excl. tax
Mini Puppy 12 V 6 l/min Jabsco 23620-4003

Jabsco

Mini Puppy 12 V 6 l/min

Ref : J015

Regular price £319.84 GBP
Sale price £319.84 GBP Regular price £365.54 GBP
excl. tax
Utility Puppy 2000 12 V 38 l/min Jabsco 23920-2423

Jabsco

Utility Puppy 2000 12 V 29.5 l/min at 3 m

Ref : J025

Regular price £385.16 GBP
Sale price £385.16 GBP Regular price £426.68 GBP
excl. tax
Utility Puppy 3000 12 V 50 l/min Jabsco 23920-2223

Jabsco

Utility Puppy 3000 12 V 44 l/min at 3 m

Ref : J027

Regular price £614.13 GBP
Sale price £614.13 GBP Regular price £701.87 GBP
excl. tax
Water Puppy 2000 24 V Jabsco 23680-4103

Jabsco

Water Puppy 2000 24 V

Ref : J020

Regular price £169.15 GBP
Sale price £169.15 GBP Regular price £193.31 GBP
excl. tax
Utility Puppy 2000 24 V 38 l/min Jabsco 23920-2523

Jabsco

Utility Puppy 2000 24 V 29.5 l/min at 3 m

Ref : J026

Regular price £339.41 GBP
Sale price £339.41 GBP Regular price £387.89 GBP
excl. tax

Learn more

Bilge pump: evacuating water from the boat’s lowest point

An electric bilge pump removes water that collects at the lowest point of the hull. This collection includes 12 V and 24 V Whale and Jabsco pumps, automatic systems, and installation accessories. Manual pumps are in the manual bilge pumps collection. For the full method, read our guide bilge pump: flow rate, installation, and safety.

The families in this collection

How to choose: actual flow rate, voltage, automation

  • Actual flow rate, not the box rating. Commercial flow rates are measured under manufacturer-defined conditions. On board, the discharge head, hose length and diameter, elbows, valves, and available voltage reduce them. Compare performance curves or tables at the intended head for your boat.
  • Voltage. Choose a pump that matches the boat’s system voltage, 12 V or 24 V, and size the cable so it receives its rated voltage when running: voltage drop slows the motor.
  • Automatic or manual control. An automatic pump has an integrated sensor or uses a separate float, such as the Field Switch. In either case, the system must remain manually testable; a three-position switch (off, automatic, forced) often provides this.
  • Two levels and an alarm. A small pump at the lowest point removes routine water; a second, higher pump takes over in abnormal rises and triggers an alarm on a separate sensor. The number and capacity of pumps depend on the boat and its requirements.

Installation: the details that make the difference

  • Place the intake at the true lowest point, both afloat and under way, with the strainer accessible for cleaning.
  • Keep the discharge hose at the recommended diameter, short, and free of crushed bends.
  • Prevent backflow and siphoning: outlet above the waterline per the manual, vented loop if needed. An inline non-return valve is not always necessary: it adds pressure loss and a risk of blockage.
  • Protect the circuit with a fuse or circuit breaker sized per the manual and clearly label the pump on the electrical panel.

Common mistakes

  • Choosing based on the rated flow alone, without accounting for head and hose.
  • Leaving an automatic pump without an alarm: a continuously running pump can mask a water ingress until batteries are drained.
  • Removing the manual pump: it remains usable after battery, wiring, sensor, or motor failure.

Skysat advice

Test the installation with water: pour a measured amount into the bilge, verify automatic activation, time the evacuation, and check the discharge. Whale states in its manuals that a bilge pump may not suffice in the event of a rapid flooding: it handles flowing water and buys time, but does not replace locating the leak.