SafetyHub 100 fuse block
Low stock
Technical specifications
Technical specifications
| Fuse type | AMI/MIDI, ATO/ATC |
| Nominal voltage | 12 |
| Amperage | 280.0 |
| Plage de calibre de fusible compatible | 1A-20A (ATO/ATC), 30A-200A (AMI/MIDI) |
| Nombre de fusibles | 7.0 |
| Mounting type | Surface-mounted installation |
| Taille des goujons | 8 |
| Taille du filetage des bornes | 8 |
| Couvercle de protection inclus | Oui |
| Protection anti-déflagrante | Oui |
| IP rating | IP66 |
| Flame retardant | Oui |
| Couple de serrage recommandé des bornes | 20.3 |
| Section de câble maximale par goujon | 120.0 |
| Dimensions (W x H x D) | 146.05 x 55.88 x 99.06 mm |
| Weight | 1.45 |
| Certifications | CE, ISO 8846, SAE J1171, E-marked |
| Ami Midi Max Amperage Per Block | 240 |
| Ami Midi Max Amperage Per Circuit | 170 |
| Ami Midi Min Cable Size Awg | 2/0 AWG |
| Ami Midi Min Cable Size Mm2 | 70 |
| Ami Midi Screw Size | M5 x .8 x 10 |
| Ami Midi Screw Torque Nm | 3.0 |
| Ato Atc Max Amperage Per Block | 50 |
| Ato Atc Max Amperage Per Circuit | 20 |
| Min Input Cable Size Awg | 4/0 AWG |
| Product type | Fuse block |
| Recommended Ring Terminal Size Imperial | 5/16” |
Detailed description
Detailed description
The Blue Sea Systems SafetyHub 100 fuse block, part number 7725B-BSS, is an electrical protection solution designed for marine environments. This consolidated module manages fuses from 1A to 200A, allowing direct installation at the battery for non-switched protection or after the battery switch for switched protection.
Design and Technical Specifications
This fuse block operates at a nominal voltage of 12V DC. It can support a maximum combined amperage of 280A with a 4/0 AWG (120 mm²) input cable. The SafetyHub 100 integrates two types of fuse blocks:
- The AMI®/MIDI® block is intended for high-current circuits, accepting fuses from 30A to 200A. It can handle a maximum amperage of 240A per block and 170A per circuit. A minimum cable of 2/0 AWG (70 mm²) is recommended for these circuits.
- The ATO®/ATC® block is used for low-current circuits, accepting fuses from 1A to 20A. Its maximum amperage is 50A per block and 20A per circuit.
The SafetyHub 100’s design ensures ignition protection in compliance with ISO 8846 and SAE J1171 standards and features an IP66 ingress protection rating, protecting against powerful water jets. The input and output studs are M8 x 1.25 in size, with a recommended tightening torque of 20.3 N·m (15 ft-lb) for the input and 3.0 N·m (27 in-lb) for the M5 x .8 x 10 screws of the ATO®/ATC® fuses.
Integration and Positioning
Compared to separate modular solutions, the SafetyHub 100 centralizes protection, reducing clutter and simplifying wiring. It serves as a compact and secure alternative to scattered installations of individual fuse holders or circuit breakers for applications requiring both low- and high-consumption circuits. The PN 7725B-BSS reference is supplied without the ATO®/ATC® circuit connector, which is included with the PN 7725 reference, offering flexibility for customized installations.
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« Robust centralization of marine electrical protections »