High-voltage BMS MG Master HV 900 V - 300 A
Detailed description
Detailed description
The Master HV is the safety and control unit for MG high-voltage battery strings. It monitors critical parameters, controls charging and discharging, and supports architectures up to 900 V DC and 300 A.
Key features
- Maximum voltage: 900 V DC
- Main contactor: 300 A
- IP65 housing and M12 CAN connection
- Emergency stop input and programmable contacts
Use case
Safety unit for high-voltage battery strings in propulsion, storage, or industrial applications.
Compatibility and prerequisites
- One Master HV unit required per battery string
- Systems from 120 to 900 V DC
- M12 CAN connection and PowerLok 300 power connection
Installation and safety
- Installation restricted to a designed and protected high-voltage architecture
- Connect emergency stop, charge/discharge permissions, and 24 V inputs
- Verify insulation, precharge, and contactor coordination before power-up
Included
- Master HV 900 V / 300 A unit
To be supplied separately
- Batteries, PowerLok connectors, CAN cables, and power cables
- High-voltage protections, external precharge, and emergency stop accessories
Shipping and handling
- Shipping weight: 13.5 kg
- Not classified as dangerous goods
Environment
- Humidity (non-condensing): ≤ 95 %
- Operating temperature range: -20 to +50 °C
Inputs and outputs
- Charge enable (relay output): 1.5 A at 30 Vdc, fuse-protected
- Discharge enable (relay output): 1.5 A at 30 Vdc, fuse-protected
- Digital input 1: 24 V / 5 mA
- Digital input 2: 24 V / 5 mA
- Digital input 3: 24 V / 5 mA
- Emergency stop connection: Yes
- Programmable contact (relay output): 1.5 A at 30 Vdc, fuse-protected
Mechanical specifications
- Data connection: CAN Bus M12
- Height: 121 mm
- Protection rating: IP65
- Length: 430 mm
- Power connection: PowerLok 300
- Weight: 9.9 kg
- Width: 329 mm
Standards and certifications
- Certifications: IEC-EN62619 (ES-TRIN)
- EMC emissions: EN-IEC 61000-6-3:2007/A1:2011/C11:2012
- EMC immunity: IEC 61000-4-6:2013
Technical specifications
- Main contactor current: 300 A
- Maximum voltage: 900 Vdc
- Supply current: 2.5 A
- Supply voltage range: 18 - 32 Vdc
- System voltage: ≥ 120 V
Logistics
- HS customs code: 8537109199
- Country of origin: Netherlands
- Shipping weight: 13.5 kg
- Classified as dangerous goods: No
Documentation
Official MG Energy datasheet - MGMHV800300
Integration advice: verify voltage, currents, protections, cooling, and interfaces of the complete system before installation.