Lynx Power In (M10)
In stock
Technical specifications
Technical specifications
| Rôle du produit | DC busbar |
| Nombre de parcs de batteries | 4.0 |
| Courant continu (A) | 1000.0 |
| Courant de crête (A) | 1000.0 |
| Max charge current (A) | 1000.0 |
| Max discharge current (A) | 1000.0 |
| Wired network | None |
| Terminal size | M10 |
| Type de connexion | M10 screw terminals, Lynx modular interconnection |
| Mounting type | Surface mount, modular (for Lynx system) |
| IP rating | IP22 |
| Operating temperature range | -40 °C to +60 °C |
| Dimensions (W x H x D) | 180 x 190 x 80 mm |
| Weight | 1.4 |
| Code-barres du produit | SK-000047049 |
| Battery technology | Universal |
| Bulk/absorption charge voltage | 0.0 |
| Matériau conducteur de la barre omnibus | Tinned copper |
| Busbar Dimensions Hxw | 8 x 30 |
| Busbar Material Finish | Tinned |
| Busbar Sections Count | 2 |
| Type de barre omnibus | Positive and negative |
| Capacity | 0.0 |
| Connection Terminal Type | M10 threaded studs |
| Cycle life | 0.0 |
| Depth of discharge (DoD) | 0.0 |
| Discharge cut-off voltage | 0.0 |
| Electrical System Role | Power distribution |
| Enclosure Material | ABS |
| Energy | 0.0 |
| Float charge voltage | 0.0 |
| Humidité maximale de fonctionnement | Max. 95 % (non-condensing) |
| Fabricant | Victron Energy |
| Max batteries in parallel | 4.0 |
| Section de câble maximale | 240 |
| Modular Mounting System | Yes |
| Mounting orientation | Horizontal |
| Type de surface de montage | Plane |
| Number Of Terminals | 4 |
| Peak discharge current | 1000.0 |
| Product range | Lynx Distribution System |
| Recommended charge current | 0.0 |
| Recommended continuous discharge current | 1000.0 |
| Reverse polarity protection | No |
| Storage temperature range | -40 °C to +60 °C |
| Supported System Voltages | 12, 24, 48 |
Detailed description
Detailed description
The Victron Energy Lynx Power In (M10) is a fundamental module of the Lynx distribution system, designed for consolidating DC connections. It consists of a positive and negative busbar with four M10 connection points for integrating batteries or DC equipment. Unlike other modules in the Lynx range, such as the Lynx Shunt VE.Can which includes battery monitoring and a fuse holder, or the Lynx Distributor which provides fused connections with monitoring, the Lynx Power In (M10) focuses solely on a simple, direct busbar function.
This module is specifically equipped with M10 terminals, suitable for systems requiring large cross-section cables to handle high currents. It integrates seamlessly with other Lynx system components, enabling the construction of a modular DC architecture for marine or mobile installations. Its design aims to simplify wiring and optimize power distribution for demanding applications.
Your payment information and data are processed securely.