Skip to content
BMS Victron VE.Bus BMS V2 pour batterie lithium marine

Collection: BMS batteries

A battery BMS protects and controls a marine lithium bank: cell monitoring, charge/discharge cutoff, low-voltage protection, temperature and overcurrent protection. The range covers 12/24/48 V architectures, from compact systems to Lynx DC bus with monitoring and protected distribution.

19 products

Lynx Power In (M10)

Victron Energy

Lynx Power In (M10)

Ref : LYN020102010

Regular price £113.09 GBP
Sale price £113.09 GBP Regular price £131.03 GBP
excl. tax
Lynx Shunt VE.Can 1000A

Victron Energy

Lynx Shunt VE.Can 1000A

Ref : LYN040102100

Regular price £295.87 GBP
Sale price £295.87 GBP Regular price £331.06 GBP
excl. tax
Lynx distributeur 1000A, M10

Victron Energy

Lynx distributor 1000A, M10

Ref : LYN060102010

Regular price £151.32 GBP
Sale price £151.32 GBP Regular price £187.80 GBP
excl. tax
Contrôleur de batterie 12/24V automatique

Samlex

Automatic 12/24V battery monitor

Ref : CB823

Regular price £69.49 GBP
Sale price £69.49 GBP Regular price £76.43 GBP
excl. tax
VE.Bus BMS

Victron Energy

VE.Bus BMS

Ref : BMS300200000

Regular price £92.92 GBP
Sale price £92.92 GBP Regular price £109.19 GBP
excl. tax
Lynx Smart BMS 500 NG (M10)

Victron Energy

Lynx Smart BMS 500 NG (M10)

Ref : LYN034160310

Regular price £543.06 GBP
Sale price £543.06 GBP Regular price £636.79 GBP
excl. tax
BMS V2 smallBMS - Victron Energy

Victron Energy

SmallBMS V2

Ref : BMS400100000

Regular price £35.35 GBP
Sale price £35.35 GBP Regular price £45.42 GBP
excl. tax
Équilibreur de batterie

Victron Energy

Battery Balancer

Ref : BBA000100100

Regular price £38.56 GBP
Sale price £38.56 GBP Regular price £45.42 GBP
excl. tax
VE.Can (M10) - Victron Energy

Victron Energy

Lynx Shunt VE.Can 1000A (M10)

Ref : LYN040102110

Regular price £291.86 GBP
Sale price £291.86 GBP Regular price £331.06 GBP
excl. tax
BMS NG - Victron Energy

Victron Energy

BMS NG

Ref : BMS300200300

Regular price £119.55 GBP
Sale price £119.55 GBP Regular price £138.01 GBP
excl. tax
smallBMS NG - Victron Energy

Victron Energy

smallBMS NG

Ref : BMS400100300

Regular price £64.79 GBP
Sale price £64.79 GBP Regular price £75.12 GBP
excl. tax
Lynx Smart BMS 500 (M8)

Victron Energy

Lynx Smart BMS 500 (M8)

Ref : LYN034160200

Regular price £748.74 GBP
Sale price £748.74 GBP Regular price £845.55 GBP
excl. tax
Lynx distributeur 1000 DC M8

Victron Energy

Lynx 1000 DC M8 distribution block

Ref : LYN060102000

Regular price £143.67 GBP
Sale price £143.67 GBP Regular price £187.80 GBP
excl. tax
Smart BMS 12/200 - Victron Energy

Victron Energy

Smart BMS 12/200

Ref : BMS210055000

Regular price £189.56 GBP
Sale price £189.56 GBP Regular price £217.50 GBP
excl. tax
Lynx Class-T Power In (M10)

Victron Energy

Lynx Class-T Power In (M10)

Ref : LYN060404010

Regular price £123.63 GBP
Sale price £123.63 GBP Regular price £158.10 GBP
excl. tax
Lynx Smart BMS 1000 NG (M10) - Victron Energy

Victron Energy

Lynx Smart BMS 1000 NG (M10)

Ref : LYN034170310

Regular price £694.66 GBP
Sale price £694.66 GBP Regular price £848.17 GBP
excl. tax
BMS V2 - Victron Energy

Victron Energy

BMS V2

Ref : BMS300200200

Regular price £125.43 GBP
Sale price £125.43 GBP Regular price £145.00 GBP
excl. tax
Gestion de batterie Smart BMS CL 12/100 - Victron Energy

Victron Energy

Smart BMS CL 12-100

Ref : BMS110022000

Regular price £117.38 GBP
Sale price £117.38 GBP Regular price £140.63 GBP
excl. tax
SolidSwitch 104

Victron Energy

SolidSwitch 104

Ref : BMS800200104

Regular price £31.25 GBP
Sale price £31.25 GBP Regular price £36.69 GBP
excl. tax

Learn more

BMS batteries: protecting and managing a marine lithium bank

A BMS (Battery Management System) is the safety layer of a lithium battery bank. It monitors cell voltages, temperatures, and current limits, then allows or cuts charge and discharge when the battery leaves its normal operating range.

On a boat, the BMS should not be seen as an optional accessory. It protects batteries from faults that are expensive at sea: overcharging, deep discharge, charging at low temperature, cell imbalance, overcurrent, or poorly controlled alternator. This collection includes Victron BMS units, Lynx modules, and distribution accessories required for a coherent lithium architecture.

What does a BMS do in a marine installation?

  • Authorize or cut charging: the BMS sends a signal to chargers, MPPTs, battery chargers/converters, or charge relays when the battery can accept current.
  • Authorize or cut loads: it protects the bank from deep discharge by controlling a relay, a load disconnect output, or a main contactor.
  • Monitor cells: a cell voltage that is too low, too high, or an out-of-range temperature must trigger an action, not just an alarm.
  • Supervise the system: in advanced architectures, the BMS reports the bank’s status to VictronConnect, a GX device, the VRM portal, or a VE.Can network.

Choosing based on battery and architecture

The first criterion is not the BMS price, but the battery series and the expected integration level. Victron Lithium Smart, Lithium NG batteries, Lynx systems, and 12/24/48 V banks do not always use the same interfaces or the same cutoff functions.

Lynx modules: distribution, shunt, and protection

A lithium installation does not end with the BMS enclosure. Lynx modules structure the DC distribution around the battery bank: Lynx Power In for battery input, Lynx Distributor for protected distribution, Lynx Shunt VE.Can for measurement, and Lynx Class-T Power In when Class-T fuse protection is required.

These modules do not replace proper sizing: continuous current, peak current, fuse type, M8/M10 stud size, and cable cross-section must match the battery bank, inverter, and onboard loads.

What a BMS does not replace

  • A properly configured battery monitor: the BMS protects; the monitor measures and helps assess range.
  • Properly sized fuses near energy sources: the BMS is not a universal short-circuit protection device.
  • Battery isolators for manual shutdown, maintenance, and bank isolation.
  • Proper alternator management: depending on the architecture, a DC/DC charger, external regulator, or current limiting may be required.

Common mistakes

  • Installing a lithium battery with a BMS incompatible with the battery series.
  • Abruptly cutting the alternator without a shedding path or protection strategy.
  • Confusing alarm output with a power cutoff device.
  • Ignoring temperature thresholds: many lithium batteries must not be charged below 0 °C without heating or adapted logic.
  • Selecting a Lynx module or shunt based solely on nominal current, without checking fuse type, connections, and available space.

Skysat advice

Before choosing a BMS, identify the exact battery, system voltage, charging sources, and loads that must be cut in case of a fault. The correct diagram specifies which device receives the allow to charge signal, which receives the allow to discharge signal, which device cuts high current, and how the alternator is protected if the BMS rejects charging.

For a small 12 V bank, a simple solution may suffice. For a large-capacity lithium bank, a powerful inverter, or a 24/48 V architecture, the system must be designed as a whole: BMS, Lynx, fuses, isolators, shunt, chargers, and wiring. It is this consistency that makes the installation reliable, not the BMS alone.