VE.Bus BMS
In stock
Technical specifications
Technical specifications
| Ac Detector Function | Restart the MultiPlus or Quattro when AC power is available, after a shutdown by the BMS due to low cell voltage. |
| Ac Detector Included | Yes |
| Battery Capacity Reserve After Shutdown Ah Per 100ah | 1 |
| Bms Interface Type | M8 circular connectors |
| Cell Balancing Daisy Chain Capable | Yes |
| Cell Overtemperature Charge Disconnect | Yes |
| Cell Overvoltage Charge Disconnect V | 4.0 |
| Cell Undervoltage Disconnect Adjustable Range V | 2.85 - 3.15 |
| Cell Undervoltage Disconnect V | 3.1 |
| Cell Undervoltage Pre Alarm Adjustable Range V | 2.85 - 3.15 |
| Cell Undervoltage Pre Alarm V | 3.1 |
| Charge Disconnect Output Current Limit Ma | 10 |
| Charge Disconnect Output State Alarm | Floating |
| Charge Disconnect Output State Normal | High |
| Compatible Relay Models | Cyrix-Li-ct (120 A), Cyrix-Li-ct (230 A), Cyrix-Li-Charge (120 A), Cyrix-Li-Charge (230 A) |
| Current Consumption Low Cell Voltage Ma | 2 |
| Consommation électrique typique | 10 |
| Led Status Charge Disconnect Alarm Color | Red |
| Led Status Load Disconnect Active Color | Blue |
| Load Disconnect Output Current Limit A | 2 |
| Load Disconnect Output State Alarm | Floating |
| Load Disconnect Output State Normal | High |
| Max Battery Bank Capacity Ah 48v | 1500 |
| Operating voltage range | 9 - 70 |
| Pre Alarm Output Current Limit A | 1 |
| Pre Alarm Output Delay Seconds | 30 |
| Pre Alarm Output Short Circuit Protected | No |
| Pre Alarm Output State Normal | Floating |
| Residual Discharge Current Damage Warning | A residual current of 10 mA can damage a 200 Ah battery if the system is left discharged for more than 8 days. |
| Compatibilité tension système | 12V,24V,48V |
Detailed description
Detailed description
The Victron Energy VE.Bus BMS is a battery management system designed to protect individual cells of Victron lithium-fer-phosphate (LiFePO4 or LFP) batteries against overvoltage, undervoltage, and overheating. Compatible with 12 V, 24 V, and 48 V systems, it integrates with Victron LiFePO4 batteries equipped with BTV (balancing, temperature and voltage monitoring) via M8 circular connectors, allowing chaining of multiple BTVs. This BMS enables the creation of battery banks up to five units in parallel and four in series, supporting for example a 48 V bank up to 1500 Ah.
Communication and system protection
This BMS communicates with MultiPlus, Quattro inverters/chargers, and Phoenix inverters via a standard UTP RJ45 cable, with an operating voltage range of 9 to 70 V DC. It ensures system safety by disconnecting loads in case of imminent cell undervoltage and by reducing charging current or disconnecting battery chargers in case of overvoltage or overheating. For non-VE.Bus products, it features dedicated outputs: a load disconnection output (max 2 A) and a charger disconnection output (max 10 mA), plus a pre-alarm output (max 1 A) that activates 30 seconds before load disconnection.
Positioning and technical specifications
The VE.Bus BMS is designed to protect Victron LiFePO4 batteries in 12 V, 24 V, and 48 V systems and communicates with MultiPlus, Quattro inverters/chargers, and Phoenix inverters via a standard UTP RJ45 cable. Blue and red LEDs indicate operating status and alerts (cell > 4 V or temperature, cell > 2.8 V). Its matte black ABS housing, with IP20 protection rating, weighs 0.1 kg and measures 105 x 78 x 32 mm, providing a compact solution for installation in protected environments.
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« Management and protection of Victron LiFePO4 batteries: essentials for VE.Bus systems »
Your payment information and data are processed securely.