| Battery technology | Plomb-acide |
| Nominal voltage | 12V et 24V |
| Wired network | Aucun |
| Max charge current (A) | 120.0 |
| Max discharge current (A) | 120.0 |
| Peak discharge current | 180.0 |
| Discharge cut-off voltage | 11.0 |
| Max batteries in parallel | 2.0 |
| Terminal size | M6 |
| Mounting orientation | Toutes orientations |
| Operating temperature range | -40 à +60 °C |
| Storage temperature range | -40 à +60 °C |
| IP rating | IP54 |
| Weight | 0.11 |
| Automatic Parallel Connection | Oui |
| Automatic Reset | Oui |
| Battery Banks | 2.0 |
| Détection automatique de la tension batterie | Oui |
| Color | Bleu |
| Combine Voltage | 13.0V - 13.8V (12V) / 26.0V - 27.6V (24V) |
| Compatible Battery Types | Plomb-acide, LiFePO4 |
| Courant continu (A) | 120.0 |
| Type de contrôle | Microprocesseur |
| Housing material | Plastique |
| Manual Override | Oui |
| Mounting type | Montage en surface |
| Open Voltage | 11.0V - 12.8V (12V) / 22.0V - 25.6V (24V) |
| Operating Current Open Ma | <4 |
| Operating Voltage Range Dc | 8 V à 36 V |
| Protection contre la surchauffe | Oui |
| Depth (mm) | 47 |
| Dimensions du produit (L x l x H) | 105 x 47 x 65 |
| Height (mm) | 65 |
| Width (mm) | 105 |
| Type de relais | Relais intelligent |
| Remote Control Input | Oui |
| Re Engagement Delay S | 10 |
| Start Assist Duration | 30 |
| Start Assist Function | Oui |
| Start Isolation | Oui |
| Transient Voltage Suppressor Integrated | Oui |
| Voltage Drop At Rated Current | Nulle |
Detailed description
Detailed description
The Victron Energy Cyrix-ct 12/24V-120A intelligent battery combiner is a microprocessor-controlled relay designed to automatically connect batteries in parallel. It closes the connection when one battery reaches a preset voltage, indicating it is charging, and disconnects the batteries when the voltage drops below the float level, indicating discharge. This system is an alternative to diode isolators, offering the advantage of no voltage drop, preventing the need to increase alternator or charger output voltages. It automatically adapts to 12V and 24V systems.
Features and performance
The Cyrix-ct 12/24V-120A includes temperature protection. If overheating occurs due to high ambient temperature or excessive current, it will open and resume normal operation after cooling. In a standard setup, the alternator is connected to the starter battery. The Cyrix-ct allows the service battery—and potentially other batteries such as a bow thruster battery—to be connected to the starter battery. Once the starter battery reaches its closing voltage, the Cyrix-ct closes to enable parallel charging of the other batteries.
Intelligent and bidirectional monitoring
The Cyrix-ct combiner measures the voltage of both connected batteries. It will close if the service battery is charged by an external battery charger. The Cyrix-ct 12/24V-120A provides a continuous current of 120 A. Its current draw is less than 4 mA when open. It has an IP54 protection rating.
Technical specifications
- Continuous current: 120 A
- Current draw when open: <4 mA
- Starting assist function: Yes (relay closed for 30 seconds)
- Protection rating: IP54
- Weight: 0.11 kg