Need help choosing?
FT Technologies Cables
8 produits
FT Technologies FT022 - RS422 Full Duplex 15m Cable for FT602-SM
Ref : FT022
Choose your option
FT Technologies FT020 - 15m FT74X-SM Digital Cable
Ref : FT020
Choose your option
FT Technologies FT001 - 15 m Digital Cable
Ref : FT001
Choose your option
FT Technologies FT009 - 1,5 m connection cable for FT74X-SM
Ref : FT009
Choose your option
FT Technologies FT018 - RS422 35 m cable for FT602
Ref : FT018
Choose your option
FT Technologies Cable 200 meters 8 wires - Connectivity
Ref : DEFAULT775
Choose your option
FT Technologies - 100 Meter Cable
Ref : DEFAULT776
Choose your option
FT Technologies FT005 - 15m Cable for 4-20mA Sensor
Ref : FT005
Choose your option
Anemometer
4 produits
FT Technologies FT602-D-SM-EV - Ultrasonic Anemometer
Ref : FT602-D-SM-EV
Choose your option
FT Technologies FT743-D-SM KIT-1.5 | ultrasonic anemometer kit
Ref : FT743-D-SM KIT-1.5
Choose your option
FT Technologies FT742-A-DM - Analog Ultrasonic Anemometer
Ref : FT742-A-DM
Choose your option
FT Technologies FT743-D-SM - digital ultrasonic anemometer
Ref : FT743-D-SM
Choose your option
Câbles et cordons
1 produit
FT Technologies FT016 - 1.5m Cable for FT602
Ref : FT016
Choose your option
Kits
3 produits
FT Technologies FT064 - Acu-Test Pack for FT602 RS422 Sensor
Ref : FT064
Choose your option
FT Technologies Acu-Test FT055 Pack - 4-20 mA analog sensor
Ref : FT055
Choose your option
FT Technologies FT058 Acu-Test - RS422 Test Pack
Ref : FT058
Choose your option
FT Technologies Compatible Accessories
1 produit
Bulgin
Bulgin PX0410/12S/6065 connector compatible with FT602-SM
Ref : 4260997
Choose your option
Learn more
See FT sensor selection · Choose between mechanical and ultrasonic
Three references to distinguish before choosing
| Catalog Reference | Documented selection identifier | Next Verification |
|---|---|---|
| FT602-D-SM-EV | The FT602-D-SM documentation describes serial and NMEA 2000 communications over CAN, configurable | Verify the delivered configuration and the contents of the EV packaging |
| FT742-A-DM | Analog variant: speed and direction outputs on 4–20 mA current loops; Direct Mount installation | Verify the receiver system inputs, loop scales, and mounting |
| FT743-D-SM | Digital Surface Mount variant; data sheet FT743-SM describes RS422/RS485 and NMEA 0183 | Verify the mode, cable, power supply, and receiving device |
Sources: FT602 documentation 9000937 Rev A01, FT742-DM A4157-6-EN and FT743-SM 9000580 Rev A02, listed below. These references do not constitute validated compatibility with your installation.
Sensor alone or FT743 kit?
The FT743-D-SM and the kit FT743-D-SM KIT-1.5 are two distinct offers. Check the packaging details before comparing the overall cost. The name « kit » does not mean that all elements for your installation are included.
The manufacturer's data sheet FT009 describes a connection cable for FT74X-SM, with one end having bare wires. This is not proof that the commercial kit contains all necessary adapters, protections, fasteners, or test equipment. Data sheet FT009, 9000579 Rev A01.
One technology, several possible installations
Acoustic resonance is an ultrasonic approach different from time-of-flight. This distinction explains the sensor's principle; it is not sufficient to designate a model for a sailboat, a fixed station, or a mobile platform. Principle Acu-Res explained by FT.
For a boat, start with the expected data, mounting, and receiving electronics. For a fixed measurement, also examine the installation and data acquisition. For wind power or a drone, the specifications must identify the intended variant: an application cited by the manufacturer does not make all its references interchangeable.
This page presents the models linked above. It does not promise online availability of FT702LT or FT205.
Cables, connectors and test equipment
Choose each accessory based on the sensor's reference, its interface, and its manual. A cable intended for one variant is not automatically suitable for another. Similarly, « Acu-Test » designates test equipment to be selected according to the interface, not a universal pack for the entire range.
Cables and associated equipment remain accessible in the grid. A Bulgin connector retains its brand: its presence in this collection does not transform it into an FT Technologies product and does not validate an association solely by its title.
Documentation and guides
| Model or Accessory | Manufacturer documentation used | Scope |
|---|---|---|
| FT602 | Manual FT602-D-SM, 9000937 Rev A01, August 2026 | Basic model, communication, and configuration; EV composition to be checked separately |
| FT742-A-DM | Data Sheet FT742-DM, A4157-6-EN | Read the analog section for variant A, not the digital model section |
| FT743-D-SM | Data Sheet FT743-SM, 9000580 Rev A02 | Sensor characteristics; not an inventory of a commercial kit |
| FT009 | Cable Data Sheet, 9000579 Rev A01 | FT74X-SM cable, to be distinguished from the purchased pack composition |
To broaden your choice: mechanical or ultrasonic on a sailboat, multi-brand comparator and NMEA 2000 architecture.
Before Ordering
Gather the exact reference, receiver interface, desired configuration, mounting, cable length and termination, power supply, and list of included items. If a compatibility point remains open, have it confirmed before purchase. Prices and availability information remain on the product pages; this page does not announce any lead times.
Frequently Asked Questions
Do the FT602, FT742, and FT743 have the same outputs?
No. Reference FT742-A-DM is analog. Documents FT602-D-SM and FT743-SM describe other interfaces and formats, to be verified with their configuration. The family name is not sufficient.
Does the FT743 kit contain everything for my installation?
Do not assume so. Check the exact contents of the pack and the needs of the receiver system. A cable data sheet does not prove the complete inventory of a commercial kit.
Are there documents in French?
French data sheets for FT602, FT742-DM, and FT743-SM are in the verified documentation folder. Consult the manufacturer's directory and check the model and revision; a translation does not replace the manual for another variant.
Is Acu-Test equipment suitable for all FT models?
Not by default. The pack reference and its interface must match the sensor. Check the equipment documentation before associating it.
Documentation verified on 16 October 2026. Official FT directory.
Commercial Transparency. Skysat markets the references presented. No exclusive distribution, universal compatibility, or immediate availability is claimed.

