Technical specifications
Technical specifications
| Nominal voltage | 12 V |
| Amperage (A) | 275.0 |
| Number of circuits (circuits) | 2.0 |
| Number of poles | Single-pole |
| Supported battery banks | 2.0 |
| Battery switch type | Power On/Off Manual |
| Battery switch control method | Manual |
| Breaker reset type | Not applicable |
| Circuit breaker type | None |
| Circuit protection method | Fuses |
| Integrated VSR | Oui |
| Mounting type | Flush or surface-mounted |
| Display type | None |
| Wired network | None |
| Certifications | CE, RoHS, ABYC |
| Maximum cable lug size | 10 mm |
| Operating temperature range | -40 to +85 °C |
| Weight (kg) | 0.25 |
| Bidirectional operation | Yes |
| Charge Algorithm Type | Automatic |
| Charge Source Types | Alternator, Battery charger |
| Discharge cut-off voltage | 10.5 |
| Dvsr Disengage Voltage 12v | 12.8 |
| Dvsr Disengage Voltage 24v | 25.6 |
| Dvsr Engage Voltage 12v | 13.7 |
| Dvsr Engage Voltage 24v | 26.8 |
| Max charge current (A) | 100.0 |
| Max discharge current (A) | 275.0 |
| Panel Shape | Cabin |
| Peak discharge current | 1250.0 |
| Recommended continuous discharge current | 275.0 |
| Storage temperature range | -55 to +100 °C |
| Terminal size | 2 x 3/8" (10mm) |
Detailed description
Detailed description
The 701BAT/DVSR BEP single-engine cluster is a compact, complete battery distribution system designed for single-engine boats with two battery banks (start and house). It integrates a 701S battery switch and a 140 A digital voltage-sensitive relay (DVSR), pre-assembled on a square "bulk" panel for simplified installation and optimized wiring.
Smart battery management for single-engine boats
This cluster centralizes power distribution at a single point. It isolates the 12.8 V banks (25.6 V in 24 V) to preserve starting capacity. Unlike a basic 701 switch or a cluster without DVSR (such as the 716-SQ-140A), this model includes automated load-sharing, eliminating the need for a 1-2-Both switch. The system is bidirectional, allowing both banks to be charged from any source. Compared to the BEP Contor Connect range (80-700-0047-00), this cluster is a direct-wired solution without remote-control electronics, offering maximum reliability and near-zero electrical consumption (1 mA in standby).
Technical specifications and robustness
The 701S switch supports 275 A continuous, 455 A intermittent, and 1,250 A at start-up, with a maximum voltage of 48 V DC. The terminals are 10 mm (3/8") tinned copper. The DVSR is rated for a maximum alternator current of 100 A and operates from -40°C to +85°C. The unit is CE-certified and meets ABYC requirements for the switch. The square panel simplifies mounting in an electrical panel.
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« Reliability and simplicity for managing two battery banks »
Your payment information and data are processed securely.