KU 01 1x14 AWG unshielded wire
Technical specifications
Technical specifications
| Number of conductors | 1.0 |
| Shielding | Unshielded |
| Conductor material | Tinned copper |
| Conductor Cross Section | 1.91 |
| Insulation Material | ETFE |
| Linear Weight | 21.4 |
| Operating temperature | -55°C to +150°C |
| Outer Diameter | 2.26 - 2.46 |
| Rated Voltage | 600 |
| Stranding | 37 x 0.25 mm |
| Wire Gauge Awg | 14 |
Detailed description
Detailed description
ELECTROAIR KU 01 wiring cable, 1 conductor 14 AWG (1.91 mm²) tinned copper, ETFE insulation, unshielded. Sold by the meter.
What ETFE changes
Ethylene tetrafluoroethylene operates continuously from −55 °C to +150 °C and resists hydrocarbons, solvents and moisture. This is the wire you install where standard PVC hardens then cracks: engine compartment, near an exhaust, damp bilge. Trade-off: it is stiffer than PVC — consider this for tight-radius runs.
Aeronautical origin
The KU 01 range is an electronic-equipment wire for aircraft, compliant with NF C 93-524. Here that translates to a finely stranded conductor (37 strands of 0.25 mm, so flexible despite the cross-section) and proven fire resistance.
Specifications
- 1 conductor, 14 AWG — 1.91 mm² cross-section
- Stranding: 37 × 0.25 mm
- Conductor: tinned copper
- Insulation: ETFE, unshielded
- Outer diameter: 2.26 to 2.46 mm
- Working voltage: 600 V
- Temperature range: −55 °C to +150 °C
- Linear resistance: 10.6 Ω/km maximum at 20 °C
- Linear mass: 21.4 kg/km
- Sold by the meter — 1 quantity = 1 meter
Standards
- NF C 93-524 (construction)
- IEC 60332-1 and C2 NF C 32-070 (fire resistance)
- FAR 25
Your payment information and data are processed securely.