Short type 2 mechanical linear actuator, 300mm, 24V
Low stock
Technical specifications
Technical specifications
| Operating voltage | 24 V |
| Bus compatibility | Propriétaire (vers calculateur de cap Raymarine) |
| Wired network | Propriétaire (vers calculateur de cap Raymarine) |
| Wireless connectivity | Non |
| Mounting type | Fixation mécanique sous le pont |
| Certifications | CE,EN60945 |
| Drive unit type | Vérin linéaire mécanique Type 2 |
| Strokes | 300 mm |
| Mounting hardware included | Oui (pied de montage, axe de barre, goupilles, rondelles, écrou) |
| Mounting orientation | Perpendiculaire au bras de barre (safran au centre) |
| Integrated rudder angle sensor | Non |
| RF300 rudder feedback | Compatible |
| Dual rudder support | Non (dépend du calculateur de cap) |
| Steering modes | N/A (dépend du calculateur de cap) |
| Disengageable | Oui |
| Alignment Tolerance Degrees | 5 |
| Gross Weight | 8.49 |
| Max Recommended Cable Length M | 16 |
| Max Recommended Cable Size Mm2 | 16 |
| Min Operating Voltage Dc | 10 |
| Service Interval Hours | 1000 |
| Service Interval Years | 2 |
| Weight | 7.722 |
Detailed description
Detailed description
Performance and mechanical integration
The Raymarine type 2 short 24V mechanical linear actuator is a high-performance autopilot actuator designed for sailboats and powerboats requiring significant thrust force. Unlike type 1 models, this type 2 actuator offers superior robustness for demanding steering systems while maintaining a compact installation footprint thanks to its 300 mm stroke. Powered by 24V, it integrates seamlessly with Raymarine course computers (such as the ACU or SPX series) to ensure rapid and surgically precise rudder response.
Installation and rudder geometry
This mechanical actuator acts directly on the rudder quadrant or tiller arm. Installation requires rigorous alignment to ensure maximum mechanical efficiency: the push arm must be strictly perpendicular to the tiller arm when the rudder is in the central position (alignment variation tolerance less than 5 degrees). Weighing 7.72 kg, its industrial design requires mounting on a structure capable of absorbing significant loads. To maintain optimal performance, Raymarine recommends a full inspection every 1000 hours of use or every 2 years.
Electrical requirements and wiring
To ensure stable 24V power supply without voltage drop (which could reset the system), cable sizing is critical. According to the manufacturer's installation specifications, 4 mm² (12 AWG) wiring is required for lengths up to 3 meters, 6 mm² (10 AWG) up to 5 meters, and up to 16 mm² (6 AWG) for lengths up to 16 meters. Adhering to these cross-sections and EMC installation guidelines (keeping at least 1 meter away from VHF cables and 2 meters from HF signals) ensures total immunity to radio interference.
Documentation
Documentation
Expert opinion
Expert opinion
Pol CONIN
Digital Manager
« Fiabilité mécanique et optimisation électrique en 24V pour les directions exigeantes »
Your payment information and data are processed securely.