Lynx Shunt VE.Can 1000A
Available in stock
Technical specifications
Technical specifications
| Product role | Battery protection interface |
| Number of battery banks | 1.0 |
| Continuous current (A) | 1000.0 |
| Max charge current (A) | 1000.0 |
| Max discharge current (A) | 1000.0 |
| Wired network | VE.Can, NMEA 2000, CAN-bus |
| VE.Can compatible | Oui |
| Compatible GX device | Oui |
| Pre-alarm output | Oui |
| Terminal size | M10 |
| Connection type | Busbar |
| Mounting type | Modular |
| Operating temperature range | -40 to +60 |
| Dimensions (W x H x D) | 180 x 190 x 80 |
| Weight | 1.4 |
| AC rating of alarm relay | 3 A, 250 Vac |
| DC rating of alarm relay | 3 A, 30 Vdc |
| Integrated battery monitoring | Oui |
| Battery technology | Universal (compatible with various battery technologies) |
| Busbar conductor material | Tinned copper |
| Busbar Terminal Size | M10 |
| Compatible Fuse Types | CNN, ANL, Mega |
| Current rating | 1000 |
| Enclosure Material | ABS |
| Fuse Dummy Busbar Included | Yes |
| Included Terminator Count | 2 |
| Mounting orientation | Flexible |
| Odoo category | Merchandise / GENHY / 38 |
| Power Consumption Detailed Ma | 60 mA @ 12V, 33 mA @ 24V, 20 mA @ 48V |
| Power Supply Connection Type | RJ10 |
| Product type | Battery shunt |
| Relay Connection Type | Screw terminal block |
| Reverse Polarity Protection Absence | Yes |
| Rj10 Cable Included | No |
| Storage temperature range | -40 to +65 |
| Power supply voltage range | 9 - 70 |
| Supported System Voltages | 12, 24 or 48 |
| Temperature Sensor Connection Type | Screw terminal block |
| Temperature Sensor Included | Yes |
Detailed description
Detailed description
The Victron Energy Lynx Shunt VE.Can 1000A is a central component of the Lynx distribution system, designed for precise battery monitoring and main circuit protection. Integrating a positive and negative busbar, a battery monitor, and a main fuse holder, it provides a consolidated solution for DC power management. This M10 model allows for a continuous current capacity of 1000 A and supports system voltages of 12, 24, or 48 V.
Integration and communication
This shunt communicates via VE.Can with Victron Energy GX devices, such as the Cerbo GX, for comprehensive monitoring and configuration. VE.Can communication ensures seamless integration into existing Victron systems, enabling access to battery data via the VRM portal for remote management. The module ships with two VE.Can RJ45 terminators to facilitate connection.
Flexibility and protection
The M10 model of the Lynx Shunt VE.Can 1000A stands out for its flexibility, including a dummy busbar that allows the main fuse to be positioned outside the shunt—a useful feature for systems requiring fuse ratings too large for the internal slot. It is compatible with CNN, ANL, or Mega fuses (sold separately), while the M8 version is limited to CNN fuses. This modularity makes it a versatile component compared to other Lynx modules, such as the Lynx Power In for simple connections, the Lynx Distributor with its four fuse connections, or the Lynx Smart BMS which integrates lithium battery management. The Lynx Shunt VE.Can M10 offers IP22 protection and operates within a temperature range of -40 °C to +60 °C.
Expert opinion
Expert opinion
« Technical analysis of the Lynx Shunt VE.Can 1000A: DC monitoring core »
Your payment information and data are processed securely.