Lynx distributor 1000A, M10
Ref : LYN060102010
Choose your option
Battery Protect 12/24V 65A
Ref : BPR000065400
Choose your option
Battery Protect 12/24V 220A
Ref : BPR000220400
Choose your option
Battery Protect 12/24V 100A
Ref : BPR000100400
Choose your option
Smart-a lithium battery 25.6V 200Ah
Ref : BAT524120610
Choose your option
Smart lithium battery 25.6V 100Ah
Ref : BAT524110610
Choose your option
Lithium battery LFP Smart 25.6V/100Ah-a (2.56KWh) NG
Ref : BAT524110620
Choose your option
12.8V/330Ah Smart Lithium Battery
Ref : BAT512132410
Choose your option
Bilge pump switch
Ref : RL035
Choose your option
Battery distributor 1E/2S/160A
Ref : RC162
Choose your option
Battery management panel with 16 single-pole circuit breakers
Ref : 800-MS3
Choose your option
Automatic 12/24V battery monitor
Ref : CB823
Choose your option
12V 50Ah blue starter battery
Ref : BA806
Choose your option
12V 100A Solenoid
Ref : 1002206
Choose your option
Spare key for M-Series battery switch - red
Ref : 7900-BSS
Choose your option
ML 24 V Solenoid
Ref : 7719-BSS
Choose your option
ML 12 V Solenoid
Ref : 7718-BSS
Choose your option
Remote-controlled battery switch ML-RBS with automatic trip manual control - 12 V
Ref : 7713-BSS
Choose your option
Dual-circuit battery switch Plus™ e-Series
Ref : 5511E-BSS
Choose your option
Dual-circuit battery switch e-Series
Ref : 5510E-BSS
Choose your option
Series L Solenoid - 250 A 12/24 V
Ref : 9012-BSS
Choose your option
e-Series ON/OFF battery switch
Ref : 9004E-BSS
Choose your option
e-Series ON/OFF battery switch
Ref : 9003E-BSS
Choose your option
Battery switch e-Series selector with AFD
Ref : 9002E-BSS
Choose your option
Series L Solenoid - 150 A 12/24 V
Ref : 7765-BSS
Choose your option
Remote-controlled battery switch ML-RBS with manual override and automatic tripping - 24 V
Ref : 7717-BSS
Choose your option
Remote battery switch ML-RBS with manual control - 24 V DC 500 A
Ref : 7702B-BSS
Choose your option
Solenoid ML - 12 V DC
Ref : 7701-BSS
Choose your option
Remote-controlled battery switch ML-RBS 12 V
Ref : 7700100B-BSS
Choose your option
Battery add-on kit - 120 A
Ref : 7650-BSS
Choose your option
Mini battery add-on kit - 65 A
Ref : 7649-BSS
Choose your option
Low-voltage disconnect m-LVD
Ref : 7635-BSS
Choose your option
Automatic charge relay ML-ACR with manual control - 24 V DC 500 A
Ref : 7623-BSS
Choose your option
Automatic charge relay ML-ACR with manual control - 12 V DC 500 A
Ref : 7622B-BSS
Choose your option
Automatic charge relay ML-ACR - 12 V DC 500 A
Ref : 7620-BSS
Choose your option
Automatic timed disconnect ATD
Ref : 7615-BSS
Choose your option
BatteryLink™ automatic charge relay - 12/24 V DC 120 A
Ref : 7611-BSS
Choose your option
Automatic charge relay SI-ACR - 12/24 V DC 120 A
Ref : 7610-BSS
Choose your option
Automatic charge relay series m - 12/24 V DC 65 A
Ref : 7601-BSS
Choose your option
Dual-circuit battery switch Plus™ mini m-Series - black
Ref : 6011200-BSS
Choose your option
Dual-circuit battery switch Plus™ Mini m-Series - red
Ref : 6011-BSS
Choose your option
m 300 A red bipolar battery switch
Ref : 6010B-BSS
Choose your option
Dual-circuit mini m-Series battery switch - black
Ref : 6010200-BSS
Choose your option
Battery selector switch series M 300 A red 3 positions
Ref : 6008B-BSS
Choose your option
Battery switch selector mini m-Series - red
Ref : 6007-BSS
Choose your option
Battery switch mini m-Series ON/OFF with button - black
Ref : 6006200-BSS
Choose your option
Battery switch on/off mini m-Series with key - red
Ref : 6005-BSS
Choose your option
Battery isolator HD-Series heavy-duty selector switch with AFD
Ref : 3003-BSS
Choose your option
HD-Series reinforced battery selector
Ref : 3002-BSS
Choose your option
Robust HD series battery switch with AFD
Ref : 3001B-BSS
Choose your option
HD-Series Heavy Duty On-Off battery switch
Ref : 3000-BSS
Choose your option
Multimeter M2 DC with SoC
Ref : 1830-BSS
Choose your option
Battery selector switch HD-Series heavy-duty 3-position with AFD
Ref : 11003-BSS
Choose your option
Battery selector switch e-Series 3-position with AFD
Ref : 11001-BSS
Choose your option
12.8V/180Ah Smart Battery
Ref : BAT512118610
Choose your option
VE.Bus BMS
Ref : BMS300200000
Choose your option
Lynx Smart BMS 500 NG (M10)
Ref : LYN034160310
Choose your option
AGM Super Cycle Battery 12V/60Ah (M6)
Ref : BAT412060082
Choose your option
Lithium SuperPack 12.8V/200Ah NG
Ref : BAT512120740
Choose your option
SmallBMS V2
Ref : BMS400100000
Choose your option
Battery Balancer
Ref : BBA000100100
Choose your option
Lynx Shunt VE.Can 1000A (M10)
Ref : LYN040102110
Choose your option
Lynx Power In (M10)
Ref : LYN020102010
Choose your option
SmartShunt 500A/50mV
Ref : SHU500050100
Choose your option
Lithium SuperPack 12.8V/20Ah (M5)
Ref : BAT512020705
Choose your option
Lithium SuperPack 12.8V/60Ah (M6)
Ref : BAT512060705
Choose your option
SmartShunt 1000A
Ref : SHU050210050
Choose your option
Choose your option
smallBMS NG
Ref : BMS400100300
Choose your option
Lynx Smart BMS 500 (M8)
Ref : LYN034160200
Choose your option
Smart Battery Sense long range (up to 10m)
Ref : SBS050150200
Choose your option
Lynx 1000 DC M8 distribution block
Ref : LYN060102000
Choose your option
Smartshunt 500A IP65
Ref : SHU065150050
Choose your option
12.8V/100Ah Smart Battery
Ref : BAT512110610
Choose your option
BatteryProtect 48V-100A
Ref : BPR048100400
Choose your option
SuperPack Battery 12.8V 200Ah
Ref : BAT512120705
Choose your option
12.8V/100Ah NG Battery
Ref : BAT512110620
Choose your option
12.8V/50Ah Smart Battery
Ref : BAT512050610
Choose your option
BMV-712 BLACK Smart
Ref : BAM030712200
Choose your option
Lithium SuperPack 25.6V/100Ah NG
Ref : BAT524110740
Choose your option
Battery 25.6V/200Ah NG
Ref : BAT524120620
Choose your option
12.8V/200Ah NG Battery
Ref : BAT512120620
Choose your option
BatteryProtect 12/24V 65A
Ref : BPR065022000
Choose your option
Smart BMS 12/200
Ref : BMS210055000
Choose your option
SmartShunt 300A
Ref : SHU050130050
Choose your option
12.8V/150Ah NG Battery
Ref : BAT512115620
Choose your option
BatteryProtect 12/24V-100A
Ref : BPR110022000
Choose your option
Lithium SuperPack 25.6V/50Ah (M8)
Ref : BAT524050705
Choose your option
Lynx Class-T Power In (M10)
Ref : LYN060404010
Choose your option
Lynx Smart BMS 1000 NG (M10)
Ref : LYN034170310
Choose your option
Choose your option
Smart Battery Protect 12/24V-220A
Ref : BPR122022000
Choose your option
Lithium SuperPack 12.8V/100Ah (M8)
Ref : BAT512110712
Choose your option
SmartShunt 2000A
Ref : SHU050220050
Choose your option
25.6V/300Ah NG Battery
Ref : BAT524130620
Choose your option
Smart BMS CL 12-100
Ref : BMS110022000
Choose your option
BatteryProtect 220A
Ref : BPR110048000
Choose your option
SolidSwitch 104
Ref : BMS800200104
Choose your option
MASTERVOLT MLI Ultra Lithium 24/1250 - 1.25 kWh
Ref : 66021250
Choose your option
MLI Ultra 12/6000 Lithium Battery
Ref : 66016000
Choose your option
MLI Ultra 12/3000 Lithium Battery
Ref : 66013000
Choose your option
Ultra Lithium MLI Battery 12 V 1.25 kWh
Ref : 66011250
Choose your option
Gel Battery MVG 12 V 200 Ah
Ref : 64002000
Choose your option
MVG gel battery 12 V 55 Ah
Ref : 64000550
Choose your option
PMI Ultra waterproof on-site installation sheet
Ref : 6369230060
Choose your option
AGM-SlimLine 12 V 185 Ah battery
Ref : 63001850
Choose your option
12 V AGM battery 270 Ah
Ref : 62002700
Choose your option
AGM Battery 12 V 225 Ah (Group 8D)
Ref : 62002250
Choose your option
AGM battery 12 V 160 Ah
Ref : 62001600
Choose your option
12 V 90 Ah AGM battery
Ref : 62000900
Choose your option
12 V 55 Ah AGM battery
Ref : 62000550
Choose your option
6 V 400 Ah AGM battery
Ref : 61004000
Choose your option
6 V 260 Ah AGM battery
Ref : 61002600
Choose your option
BMV-712 Smart
Ref : BAM030712000
Choose your option
Battery monitor for NMEA 2000 network
Ref : ZDIGISSBM100
Choose your option
SmartShunt IP65 500A Battery Controller
Ref : SHU050150050
Choose your option
MasterShunt 500 CZone Battery Controller
Ref : 77020115
Choose your option
BattMan Pro. Battery Controller
Ref : 70405070
Choose your option
MLI Ultra 24/6000 lithium battery
Ref : 66026000
Choose your option
Learn more
Boat electrical storage: batteries, protection, and energy management
Boat electrical storage isn't just about choosing a capacity in amp-hours. A reliable installation combines a battery suited to the sailing program, a BMS or cut-off protection when the chemistry requires it, a way to measure the actual state of the battery bank, and switching devices sized for the vessel's currents.
This collection groups the components that structure the battery bank: lithium and lead batteries, BMS, battery disconnect switches, battery monitors, charge relays, contactors, and disconnectors. The goal is to build a readable, maintainable architecture capable of powering instruments, the autopilot, VHF, windlass, lighting, refrigeration, and comfort systems without risking the starter battery.
Major storage categories
- Batteries: LiFePO4/LFP batteries, service batteries, and batteries suited for 12 V, 24 V, or 48 V banks. Victron Smart, SuperPack, Lithium NG, Mastervolt, and MG Energy ranges should not be chosen solely based on capacity: check charge current, discharge current, required BMS, and charging temperature.
- BMS batteries: smallBMS, BMS NG, Smart BMS, and Lynx Smart BMS modules to monitor lithium cells, authorize or cut charge and discharge, and prevent overcharging, deep discharge, or charging at low temperature.
- Battery disconnect switches: manual or remote-controlled switches to isolate a bank, cut a main circuit, or temporarily combine two batteries. The m-Series, e-Series, and ML-RBS families do not cover the same currents or uses.
- Battery monitors: shunts and displays like SmartShunt, BMV, or M2 DC to measure voltage, current, state of charge, and history. A monitor informs; it does not replace electrical protection.
- Charge relays: ACR, SI-ACR, BatteryLink, and ML-ACR to automatically charge two battery banks from a common source, then isolate them when voltage drops.
- Contactors, solenoids & disconnectors: L-Series solenoids, ML contactors, m-LVD, and ATD to control or cut a power circuit, protect against low-voltage discharge, or delay a cut-off.
Lithium, lead, AGM: the choice depends on the architecture
Lithium LiFePO4 offers weight savings, greater usable depth of discharge, and more stable voltage. In return, it requires a more rigorous architecture: compatible BMS, charge and discharge cut-off, alternator protection, properly sized fuses, and sometimes a DC/DC charger or external regulator depending on the engine and installed bank.
Lead, AGM, or gel batteries remain relevant for simple uses, engine starter batteries, or installations where robustness and tolerance outweigh energy density. They handle repeated deep discharges less well, but their integration can be more straightforward in an existing architecture.
What to size before ordering
- Daily consumption: instruments, autopilot, lighting, refrigeration, communication, pump, computer, inverter. Without an energy balance, battery capacity is a fragile estimate.
- Maximum currents: windlass, thruster, inverter, starter, charger, and alternator dictate cable cross-sections, fuses, battery disconnect switches, and contactors.
- Charging sources: engine alternator, shore power charger, MPPT solar, hydrogenerator, generator, or inverter-charger have different profiles and limits.
- Bank separation: the starter battery must remain available. Charge relays and ACRs serve a different purpose than contactors or low-voltage disconnectors.
- Monitoring: a bank that isn't measured often leads to misinterpretation. A correctly configured shunt is more reliable than a voltage reading alone.
Common mistakes
- Comparing two batteries solely on Ah without considering voltage, chemistry, permissible current, and BMS compatibility.
- Replacing lead with lithium without revising the alternator charging, cut-off thresholds, and main fuse.
- Installing an undersized battery disconnect switch or contactor relative to the actual current of the windlass or inverter.
- Confusing monitor, BMS, and circuit breaker: measuring, protecting, and cutting are three different functions.
- Neglecting maintenance: accessibility of fuses, cable labeling, terminal tightening, and onboard schematic documentation.
Skysat advice
For a reliable storage installation, start with the complete schematic rather than an isolated battery spec sheet. Define consumers, charging sources, battery chemistry, protections, and cut-off modes. A high-end lithium battery poorly integrated can be less reliable than a simpler bank that is properly protected.
On a refit, we first check the existing wiring, grounds, DC distribution, available space, ventilation, and alternator capacity. Only then do we select the battery, BMS, monitor, and switching devices. It is this overall coherence that makes the difference at sea.